aboutsummaryrefslogtreecommitdiff
path: root/gcc/testsuite/ada/acats/tests/c9/c974006.a
blob: f6f4d92e869c24551c7081f6441acc9e416a9380 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
-- C974006.A
--
--                             Grant of Unlimited Rights
--
--     Under contracts F33600-87-D-0337, F33600-84-D-0280, MDA903-79-C-0687,
--     F08630-91-C-0015, and DCA100-97-D-0025, the U.S. Government obtained 
--     unlimited rights in the software and documentation contained herein.
--     Unlimited rights are defined in DFAR 252.227-7013(a)(19).  By making 
--     this public release, the Government intends to confer upon all 
--     recipients unlimited rights  equal to those held by the Government.  
--     These rights include rights to use, duplicate, release or disclose the 
--     released technical data and computer software in whole or in part, in 
--     any manner and for any purpose whatsoever, and to have or permit others 
--     to do so.
--
--                                    DISCLAIMER
--
--     ALL MATERIALS OR INFORMATION HEREIN RELEASED, MADE AVAILABLE OR
--     DISCLOSED ARE AS IS.  THE GOVERNMENT MAKES NO EXPRESS OR IMPLIED 
--     WARRANTY AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITIONS OF THE
--     SOFTWARE, DOCUMENTATION OR OTHER INFORMATION RELEASED, MADE AVAILABLE 
--     OR DISCLOSED, OR THE OWNERSHIP, MERCHANTABILITY, OR FITNESS FOR A
--     PARTICULAR PURPOSE OF SAID MATERIAL.
--*
--
-- OBJECTIVE:
--      Check that the sequence of statements of the triggering alternative
--      of an asynchronous select statement is executed if the triggering
--      statement is a protected entry call, and the entry is accepted
--      immediately. Check that the corresponding entry body is executed
--      before the sequence of statements of the triggering alternative.
--      Check that the abortable part is not executed.
--
-- TEST DESCRIPTION:
--      Declare a main procedure containing an asynchronous select with a
--      protected entry call as triggering statement. Declare a protected
--      procedure which sets the protected entry's barrier true. Force the
--      entry call to be accepted immediately by calling this protected
--      procedure prior to the asynchronous select. Since the entry call
--      is accepted immediately, the abortable part should never start. When
--      entry call completes, the sequence of statements of the triggering
--      alternative should execute.
--
--
-- CHANGE HISTORY:
--      06 Dec 94   SAIC    ACVC 2.0
--
--!


package C974006_0 is  -- Automated teller machine abstraction.


   -- Flag for testing purposes:

   Entry_Body_Executed : Boolean := False;


   type Key_Enum is (None, Cancel, Deposit, Withdraw);

   type Card_Number_Type is private;
   type Card_PIN_Type    is private;
   type ATM_Card_Type    is private;


   Transaction_Canceled : exception;


   protected type ATM_Keyboard_Protected is
      entry Cancel_Pressed;
      procedure Read_Key;
   private
      Last_Key_Pressed : Key_Enum := None;
   end ATM_Keyboard_Protected;


   procedure Read_Card (Card : in out ATM_Card_Type);

   procedure Validate_Card (Card : in ATM_Card_Type);

   procedure Perform_Transaction (Card : in ATM_Card_Type);

private

   type Card_Number_Type is range   1 .. 9999;
   type Card_PIN_Type    is range 100 ..  999;

   type ATM_Card_Type is record
      Number : Card_Number_Type;
      PIN    : Card_PIN_Type;
   end record;

end C974006_0;


     --==================================================================--


with Report;
package body C974006_0 is


   protected body ATM_Keyboard_Protected is

      entry Cancel_Pressed when (Last_Key_Pressed = Cancel) is
      begin
         Entry_Body_Executed := True;
      end Cancel_Pressed;

      procedure Read_Key is
      begin
         -- Simulate a procedure which processes user keyboard input, and
         -- which is called by some interrupt handler.
         Last_Key_Pressed := Cancel;
      end Read_Key;

   end ATM_Keyboard_Protected;


   procedure Read_Card (Card : in out ATM_Card_Type) is
   begin
      Card.Number := 9999;
      Card.PIN    := 111;
   end Read_Card;


   procedure Validate_Card (Card : in ATM_Card_Type) is
   begin
      Report.Failed ("Abortable part executed");
   end Validate_Card;


   procedure Perform_Transaction (Card : in ATM_Card_Type) is
   begin
      Report.Failed ("Triggering alternative sequence of statements " &
                      "not fully executed");
   end Perform_Transaction;


end C974006_0;


     --==================================================================--


with Report;

with C974006_0;  -- Automated teller machine abstraction.
use  C974006_0;

procedure C974006 is

   Card_Data : ATM_Card_Type;

begin

   Report.Test ("C974006", "ATC: trigger is protected entry call" &
                              " and completes first");

   Read_Card (Card_Data);

   declare
      Keyboard : C974006_0.ATM_Keyboard_Protected;
   begin

      -- Simulate the situation where the user hits cancel before the
      -- validation process can start:
      Keyboard.Read_Key;                 -- Force Keyboard.Cancel_Pressed to
                                         -- be accepted immediately.

      --                                    --
      -- Asynchronous select is tested here --
      --                                    --

      select
         Keyboard.Cancel_Pressed;        -- Entry call is accepted immediately,
                                         -- so abortable part does NOT start.

         if not Entry_Body_Executed then -- Executes after entry completes.
            Report.Failed ("Triggering alternative sequence of statements " &
                           "executed before triggering statement complete");
         end if;

         raise Transaction_Canceled;     -- Control passes to exception
                                         -- handler.
      then abort
         Validate_Card (Card_Data);      -- Should not be executed.
      end select;
      Perform_Transaction (Card_Data);   -- Should not be reached.
   exception
      when Transaction_Canceled =>
         null;
   end;

   Report.Result;

end C974006;