aboutsummaryrefslogtreecommitdiff
path: root/Documentation/power
diff options
context:
space:
mode:
authorChanwoo Choi <cw00.choi@samsung.com>2012-05-05 06:26:47 -0700
committerAnton Vorontsov <anton.vorontsov@linaro.org>2012-05-05 19:51:58 -0700
commitdfeccb12b4614befc49a92eb121c2211294ca669 (patch)
tree90098ac099d9915af3e941a4d6012507dc10a8df /Documentation/power
parentd829dc75bafb10754f35fb8895e5143d20267b04 (diff)
charger-manager: Provide cm_notify_event function for in-kernel use
By using cm_notify_event function, charger driver can report several charger events (e.g. battery full and external power in/out, etc) to Charger-Manager. Charger-Manager can properly and immediately control chargers by the reported event. Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com> Signed-off-by: Donggeun Kim <dg77.kim@samsung.com> Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com> Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
Diffstat (limited to 'Documentation/power')
-rw-r--r--Documentation/power/charger-manager.txt16
1 files changed, 15 insertions, 1 deletions
diff --git a/Documentation/power/charger-manager.txt b/Documentation/power/charger-manager.txt
index 9b3863386e5..b4f7f4b23f6 100644
--- a/Documentation/power/charger-manager.txt
+++ b/Documentation/power/charger-manager.txt
@@ -50,6 +50,10 @@ Charger Manager supports the following:
restarts charging. This check is also performed while suspended by
setting wakeup time accordingly and using suspend_again.
+* Support for uevent-notify
+ With the charger-related events, the device sends
+ notification to users with UEVENT.
+
2. Global Charger-Manager Data related with suspend_again
========================================================
In order to setup Charger Manager with suspend-again feature
@@ -174,7 +178,17 @@ bool measure_battery_temp;
the value of measure_battery_temp.
};
-5. Other Considerations
+5. Notify Charger-Manager of charger events: cm_notify_event()
+=========================================================
+If there is an charger event is required to notify
+Charger Manager, a charger device driver that triggers the event can call
+cm_notify_event(psy, type, msg) to notify the corresponding Charger Manager.
+In the function, psy is the charger driver's power_supply pointer, which is
+associated with Charger-Manager. The parameter "type"
+is the same as irq's type (enum cm_event_types). The event message "msg" is
+optional and is effective only if the event type is "UNDESCRIBED" or "OTHERS".
+
+6. Other Considerations
=======================
At the charger/battery-related events such as battery-pulled-out,