aboutsummaryrefslogtreecommitdiff
path: root/Documentation
diff options
context:
space:
mode:
authorJean Delvare <khali@linux-fr.org>2009-12-09 20:36:07 +0100
committerJean Delvare <khali@linux-fr.org>2009-12-09 20:36:07 +0100
commitebfaf1fbb6010204e973e329034d0004d6521503 (patch)
tree1048d124e52a5074994400556bc10b08d3bc2a00 /Documentation
parentd07ca4ad2f67ebb1bf48a2308a7a0cd81ef8f70a (diff)
hwmon: (adt7475) Voltage attenuators can be bypassed
It is possible to bypass the voltage attenuators on the +2.5V, Vccp, +5V and +12V voltage monitoring inputs. This is useful to connect other voltage channels than the ones the monitoring chip was originally designed for. When this feature is enabled, we must not include the scaling factors in our computations. Signed-off-by: Jean Delvare <khali@linux-fr.org> Cc: Hans de Goede <hdegoede@redhat.com> Cc: Jordan Crouse <jordan@cosmicpenguin.net> Cc: "Darrick J. Wong" <djwong@us.ibm.com>
Diffstat (limited to 'Documentation')
0 files changed, 0 insertions, 0 deletions