From 60c1f31fc5dfdbef388f47739e14c3cd85ad17e2 Mon Sep 17 00:00:00 2001 From: Evgeniy Dushistov Date: Thu, 1 Aug 2013 23:23:48 +0400 Subject: hwmon: (ads1015) Add support for ADS1115 This patch adds support for ads1115 device to ads1015 driver. Based on work of Emiliano Carnati . Tested on ARM CPU based board. Signed-off-by: Evgeniy A. Dushistov Signed-off-by: Guenter Roeck --- Documentation/hwmon/ads1015 | 8 ++++++-- 1 file changed, 6 insertions(+), 2 deletions(-) (limited to 'Documentation') diff --git a/Documentation/hwmon/ads1015 b/Documentation/hwmon/ads1015 index f6fe9c20373..063b80d857b 100644 --- a/Documentation/hwmon/ads1015 +++ b/Documentation/hwmon/ads1015 @@ -6,6 +6,10 @@ Supported chips: Prefix: 'ads1015' Datasheet: Publicly available at the Texas Instruments website : http://focus.ti.com/lit/ds/symlink/ads1015.pdf + * Texas Instruments ADS1115 + Prefix: 'ads1115' + Datasheet: Publicly available at the Texas Instruments website : + http://focus.ti.com/lit/ds/symlink/ads1115.pdf Authors: Dirk Eibach, Guntermann & Drunck GmbH @@ -13,9 +17,9 @@ Authors: Description ----------- -This driver implements support for the Texas Instruments ADS1015. +This driver implements support for the Texas Instruments ADS1015/ADS1115. -This device is a 12-bit A-D converter with 4 inputs. +This device is a 12/16-bit A-D converter with 4 inputs. The inputs can be used single ended or in certain differential combinations. -- cgit v1.2.3 From 30b146d1cb5e7560192057098eb705118bd5511f Mon Sep 17 00:00:00 2001 From: Wei Hu Date: Fri, 23 Aug 2013 13:14:03 -0700 Subject: hwmon: (k10temp) Add support for Fam16h (Kabini) The temperature reporting interface stays the same, so we just add the PCI-ID to the list. Verified on AMD Olive Hill. Signed-off-by: Wei Hu Acked-by: Clemens Ladisch Cc: stable@vger.kernel.org # 3.10+ Signed-off-by: Guenter Roeck --- Documentation/hwmon/k10temp | 1 + 1 file changed, 1 insertion(+) (limited to 'Documentation') diff --git a/Documentation/hwmon/k10temp b/Documentation/hwmon/k10temp index 90956b61802..4dfdc8f8363 100644 --- a/Documentation/hwmon/k10temp +++ b/Documentation/hwmon/k10temp @@ -12,6 +12,7 @@ Supported chips: * AMD Family 12h processors: "Llano" (E2/A4/A6/A8-Series) * AMD Family 14h processors: "Brazos" (C/E/G/Z-Series) * AMD Family 15h processors: "Bulldozer" (FX-Series), "Trinity" +* AMD Family 16h processors: "Kabini" Prefix: 'k10temp' Addresses scanned: PCI space -- cgit v1.2.3 From f060c658b820141f18abd7b71586d628464a03ea Mon Sep 17 00:00:00 2001 From: William Markezana Date: Thu, 29 Aug 2013 13:51:42 +0200 Subject: hwmon: (htu21) Add Measurement Specialties HTU21D support Signed-off-by: William Markezana [Guenter Roeck - minor formatting changes] Signed-off-by: Guenter Roeck --- Documentation/hwmon/htu21 | 46 ++++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 46 insertions(+) create mode 100644 Documentation/hwmon/htu21 (limited to 'Documentation') diff --git a/Documentation/hwmon/htu21 b/Documentation/hwmon/htu21 new file mode 100644 index 00000000000..f39a215fb6a --- /dev/null +++ b/Documentation/hwmon/htu21 @@ -0,0 +1,46 @@ +Kernel driver htu21 +=================== + +Supported chips: + * Measurement Specialties HTU21D + Prefix: 'htu21' + Addresses scanned: none + Datasheet: Publicly available at the Measurement Specialties website + http://www.meas-spec.com/downloads/HTU21D.pdf + + +Author: + William Markezana + +Description +----------- + +The HTU21D is a humidity and temperature sensor in a DFN package of +only 3 x 3 mm footprint and 0.9 mm height. + +The devices communicate with the I2C protocol. All sensors are set to the +same I2C address 0x40, so an entry with I2C_BOARD_INFO("htu21", 0x40) can +be used in the board setup code. + +This driver does not auto-detect devices. You will have to instantiate the +devices explicitly. Please see Documentation/i2c/instantiating-devices +for details. + +sysfs-Interface +--------------- + +temp1_input - temperature input +humidity1_input - humidity input + +Notes +----- + +The driver uses the default resolution settings of 12 bit for humidity and 14 +bit for temperature, which results in typical measurement times of 11 ms for +humidity and 44 ms for temperature. To keep self heating below 0.1 degree +Celsius, the device should not be active for more than 10% of the time. For +this reason, the driver performs no more than two measurements per second and +reports cached information if polled more frequently. + +Different resolutions, the on-chip heater, using the CRC checksum and reading +the serial number are not supported yet. -- cgit v1.2.3