Kernel driver exynos4_tmu ================= Supported chips: * ARM SAMSUNG EXYNOS4 series of SoC Prefix: 'exynos4-tmu' Datasheet: Not publicly available Authors: Donggeun Kim Description ----------- This driver allows to read temperature inside SAMSUNG EXYNOS4 series of SoC. The chip only exposes the measured 8-bit temperature code value through a register. Temperature can be taken from the temperature code. There are three equations converting from temperature to temperature code. The three equations are: 1. Two point trimming Tc = (T - 25) * (TI2 - TI1) / (85 - 25) + TI1 2. One point trimming Tc = T + TI1 - 25 3. No trimming Tc = T + 50 Tc: Temperature code, T: Temperature, TI1: Trimming info for 25 degree Celsius (stored at TRIMINFO register) Temperature code measured at 25 degree Celsius which is unchanged TI2: Trimming info for 85 degree Celsius (stored at TRIMINFO register) Temperature code measured at 85 degree Celsius which is unchanged TMU(Thermal Management Unit) in EXYNOS4 generates interrupt when temperature exceeds pre-defined levels. The maximum number of configurable threshold is four. The threshold levels are defined as follows: Level_0: current temperature > trigger_level_0 + threshold Level_1: current temperature > trigger_level_1 + threshold Level_2: current temperature > trigger_level_2 + threshold Level_3: current temperature > trigger_level_3 + threshold The threshold and each trigger_level are set through the corresponding registers. When an interrupt occurs, this driver notify user space of one of four threshold levels for the interrupt through kobject_uevent_env and sysfs_notify functions. Although an interrupt condition for level_0 can be set, it is not notified to user space through sysfs_notify function. Sysfs Interface --------------- name name of the temperature sensor RO temp1_input temperature RO temp1_max temperature for level_1 interrupt RO temp1_crit temperature for level_2 interrupt RO temp1_emergency temperature for level_3 interrupt RO temp1_max_alarm alarm for level_1 interrupt RO temp1_crit_alarm alarm for level_2 interrupt RO temp1_emergency_alarm alarm for level_3 interrupt RO